KAESER FILTER series, to 1130 scfm

Cost-effective solutions for optimal compressed air quality

KAESER FILTER products are the key components for producing compressed air to all purity classes as per ISO 8573-1—and all with exceptionally low differential pressure. Moreover, their service-friendly design not only allows simple, error-free opening and closing of the filter housing, but also enables quick and clean element changes.

  • Flow rate: 20 to 1130 cfm
  • Max. working pressure 232 psig
  • Max. operating temperature 150 °F

Your advantages

  • Standard-compliant purity:
    The KAESER FILTER range uses modern deep-pleated filter media to remove particles and aerosols. A highly effective carbon fiber mat traps oil vapors. The outstanding performance data of KAESER FILTERS were calculated according to ISO 12500 and validated by Lloyd's Register, the independent certification organization.
  • Low pressure loss – high savings:
    KAESER FILTER products feature generously sized housings and filter surfaces, innovative flow dynamics and high-performance filter media. They feature up to 50% lower pressure loss than other available filters – a value which remains virtually constant over the entire service life of the filter element. This means lower costs and CO2 emissions as well as reduced load on upstream compressors.
  • Service-friendly design – straightforward handling
    KAESER FILTER products feature a corrosion-resistant aluminum housing and a stable filter element. The practical bayonet lock ensures automatic positioning of the housing and element seals, which prevents the filter housing from being sealed unless a filter element has been inserted. A locking screw prevents unintentional opening of the housing when under pressure and also provides housing venting.
 

Product details

Pure compressed air for every application
Degree of filtration KB Coalescence filter
Basic
KE Coalescence filter
Extra
KD Particulate filter
Dust
KA Activated carbon filter
Adsorption
KBE Extra Combination KEA Carbon Combination
Initial differential pressure with saturation <2.2 psi < 3.0 psi < 0.8 psi
(New, dry)
0.8 psi
(New, dry)
< 5.2 psi < 3.8 psi
Aerosol content at inlet 10 mg/m³ 10 mg/m³ 10 mg/m³ 10 mg/m³
Residual aerosol content at outlet according to ISO 12500-1 < 0.01 mg/m³ < 0.01 mg/m³ < 0.01 mg/m³ 0.003 mg/m³
(Total oil content)
Filter medium Deep-pleated with support structure and polyester drainage fibre Deeply pleated with supporting structure High-efficiency carbon fleece
Application Filtration of solid and liquid aerosols and solid particles Same application as KB, but for higher compressed air quality; alternatively: micro-particle filter to KD degree of filtration Exclusively for the filtration of solid particles Exclusively for the removal of oil vapors Combination of KB and KE; application as KE, but for higher assurance of compressed air quality Combination of KE and KA, filtration of aerosols, solid matter particles and oil vapors
Minimal pressure loss, maximum savings
KAESER FILTERS: Minimal pressure loss, maximum savings

Life cycle cost savings

Pressure loss is the most significant factor affecting the efficiency of compressed air filters. KAESER FILTER products feature generously sized housings and filter surfaces, innovative flow dynamics, and high-performance filter media. These features result in up to 50 % lower pressure loss in comparison to other typically available filters. Moreover, this outstanding filtration performance remains virtually constant throughout their entire service life. This reduces the load on upstream compressors, thereby offering the potential for significant reductions in costs and CO2 emissions.

Want to find out more about how Kaeser is cutting life cycle costs?

Design and Function
KAESER filters – Design and function
  1. Compressed air inlet
  2. Element head with housing and element sealing
  3. Filter element
  4. Condensate outlet (with automatic condensate separator in this model)
  5. Compressed air outlet
  6. Stop screw
  7. Bayonet lock with limit stop
  8. Vent hole
Technical specifications KA

Standard version

ModelF6KA F9KA F16KA
Flow rate cfm 21 32 57
Compressed air connection½, ¾ ½, ¾ ¾, 1
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 5 5 7
Condensate drain voltage- 24...48 VAC; 18...72 VDC -

ModelF22KA F26KA F46KA
Flow rate cfm 78 92 162
Compressed air connection¾, 1 ¾, 1 1¼, 1½, 2
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 7 7 16
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC

ModelF83KA F110KA F142KA
Flow rate cfm 293 389 502
Compressed air connection1¼, 1½, 2 1¼, 1½, 2 1¼, 1½, 2
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 18 21 22
Condensate drain voltage- - -

ModelF184KA F250KA F320KA
Flow rate cfm 650 883 1,130
Compressed air connection2½, 3 2½, 3 2½, 3
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 35 39 44
Condensate drain voltage- - -

Technical specifications KB

Standard version

ModelF6KB F9KB F16KB
Flow rate cfm 21 32 57
Compressed air connection½, ¾ ½, ¾ ¾, 1
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 8 8 9
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC

ModelF22KB F26KB F46KB
Flow rate cfm 78 92 162
Compressed air connection¾, 1 ¾, 1 1¼, 1½, 2
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 10 10 19
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC

ModelF83KB F110KB F142KB
Flow rate cfm 293 389 502
Compressed air connection1¼, 1½, 2 1¼, 1½, 2 1¼, 1½, 2
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 21 24 24
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC

ModelF184KB F250KB F320KB
Flow rate cfm 650 883 1,130
Compressed air connection2½, 3 2½, 3 2½, 3
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 37 41 45
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC

Technical specifications KD

Standard version

ModelF6KD F9KD F16KD
Flow rate cfm 21 32 57
Compressed air connection½, ¾ ½, ¾ ¾, 1
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 6 6 7
Condensate drain voltage- - -

ModelF22KD F26KD F46KD
Flow rate cfm 78 92 162
Compressed air connection¾, 1 ¾, 1 1¼, 1½, 2
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 8 8 17
Condensate drain voltage- - -

ModelF83KD F110KD F142KD
Flow rate cfm 293 389 502
Compressed air connection1¼, 1½, 2 1¼, 1½, 2 1¼, 1½, 2
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 18 22 22
Condensate drain voltage- - -

ModelF184KD F250KD F320KD
Flow rate cfm 650 883 1,130
Compressed air connection2½, 3 2½, 3 2½, 3
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 35 39 44
Condensate drain voltage- - -

Technical specifications KE

Standard version

ModelF6KE F9KE F16KE
Flow rate cfm 21 32 57
Compressed air connection½, ¾ ½, ¾ ¾, 1
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 8 8 9
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC

ModelF22KE F26KE F46KE
Flow rate cfm 78 92 162
Compressed air connection¾, 1 ¾, 1 1¼, 1½, 2
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 10 10 19
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC

ModelF83KE F110KE F142KE
Flow rate cfm 293 389 502
Compressed air connection1¼, 1½, 2 1¼, 1½, 2 1¼, 1½, 2
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 21 24 24
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC

ModelF184KE F250KE F320KE
Flow rate cfm 650 883 1,130
Compressed air connection2½, 3 2½, 3 2½, 3
Working pressure psi 30 - 232 30 - 232 30 - 232
Ambient temperature °F 38 - 122 38 - 122 38 - 122
Inlet temperature °F 38 - 150 38 - 150 38 - 150
Weight lb 37 41 45
Condensate drain voltage95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC 95...240 VAC; 100...125 VDC